top of page
VaporArmour_Logo350x841.png
Warranty Logos.JPG

ELIMINATES VAPOR DRIVE IN EVERY

THERMAL-CONTROLLED FACILITY

Exterior Compression Seal.JPG
• carries a warranty guaranteeing to eradicate vapor drive for 15 years
• decreases energy costs by 17-22% or more
• helps stop product contamination from inconsistent temperatures
• complies with FSMA
• complies with Insurance and Banking Audits
• removes unnecessary labor costs
• reduces defrost cycle and extends compressor’s life-span
Interior Wall Partition.JPG
• carries a warranty guaranteeing to eradicate vapor drive for 15 years
• decreases energy costs by 17-22% or more
• helps stop product contamination from inconsistent temperatures
• complies with FSMA
• complies with Insurance and Banking Audits
• removes unnecessary labor costs
• reduces defrost cycle and extends compressor’s life-span
Stack Joint copy.jpg
As the thermal-controlled facilities height expands up to 120’, another opportunity to save energy is to seal the stack joints. Building movement of a thermal-controlled building and the ensuing pressure created puts extreme stress on these penetrations creating vapor barrier discontinuity. An intact vapor barrier over the stack joints prevents air infiltration. Vapor Armour’s Horizontal Stack Joint permanently seals this connection.
  • Eliminates air infiltration, ice and condensation
  • Reduces energy usage by 15–21%
  • Is compatible with any construction type (IMP, Concrete, Wood, etc)
  • Is FSMA compliant
  • Includes a 15-year “No Ice-No Condensation-No Cost” Warranty
Vapor Shield.JPG
From our 17 years’ experience, another opportunity to save energy is to seal the expansion joints. Building movement of a thermal-controlled building and the ensuing pressure created puts extreme stress on the expansion joints creating
vapor barrier discontinuity. An intact vapor barrier covering the expansion joints prevents air infiltration. Vapor Armour’s patented Vapor Shield™ detail permanently seals this connection. Eliminates air infiltration, ice, and condensation.
• will not disrupt business operations during installation
• is compatible with every roof system
• immediately eliminates air infiltration
• includes a 15-year ‘No Ice. No Condensation. No Cost.’ warranty
• has a retrofit thermal value of R-20, R-50 and R-80
Vapor Lock.JPG
Sometimes building movement literally forces the IMP joints to burst at the seams - especially if the butyl sealant is non-existent or poorly applied. This air infiltration can be permanently eliminated from IMP joints. An intact vapor barrier “locking” the IMP seams prevents air infiltration. Vapor Armour’s patented Vapor Lock™ permanently seals these connections.
  • Eliminates air infiltration, ice and condensation
  • Reduces energy usage by 15–21%
  • Is compatible with any construction type (IMP, Concrete, Wood, etc)
  • Is FSMA compliant
  • Includes a 15-year “No Ice-No Condensation-No Cost” Warranty
Pipe Lock.JPG
In hurricane and seismic risk areas, the ammonia piping constructed through the roof deck is often poorly sealed – if at all. Building movement of a thermal-controlled building and the ensuing pressure created puts extreme stress on these penetrations creating vapor barrier discontinuity. An intact vapor barrier “locking” the penetrating pipes prevents air infiltration. Vapor Armour’s patented Pipe Lock™ permanently seals this connection.
  • Eliminates air infiltration, ice and condensation
  • Reduces energy usage by 15–21%
  • Is compatible with any construction type (IMP, Concrete, Wood, etc)
  • Is FSMA compliant
  • Includes a 15-year “No Ice-No Condensation-No Cost” Warranty

CUSTOMIZED APPLICATIONS

Over and above our common seals (Exterior Compression™, Interior Separation™, Pipe Lock™, Vapor Lock™) we are often tasked with one-off custom approaches. Again, Vapor Armour™ STOPS vapor drive, STOPS air. Here we are stopping air, in details that are not limited to the normal building envelope.
Custom 1.JPG
Approximately 15 separate electrical conduits enter a 38° cooler
Custom 2.JPG
Vertical Seal between a 38° cooler and -10° freezer

1. We take regular and thermal imaging pictures of your  ice and condensation concerns.

2. We walk the exterior perimeter and the cooler/freezer interiors.

3. If necessary, we obtain core  samples from the exterior roof deck to ascertain the extent of the ice contamination

4. We talk with you and your team regarding where the vapor barrier has been breached.

5. We will then prepare our Forensic Evaluation report have a conference with you to discuss its findings and dimensions to create a scope of work and Budget.

6. Finally, Vapor Armour will send you a current Google Earth photo of your facility, highlighting the ice/condensation concerns, and a proposal for your budgets

NOW

AVAILABLE

1. You take pictures of your icing and condensing concerns. You send those through to us by email: eric@vaporarmour.com

2. We talk with you and your team regarding where the vapor barrier has been breached (call us at 503-890-7793 or we can talk over our Free Conference call phone)

3. We will then have an interactive video conference meeting (ZOOM) with you to discuss our Virtual Forensic Evaluation findings and dimensions to create a scope of work and Budget.

4. Finally, Vapor Armour will send you a current Google Earth photo of your facility, highlighting the ice/condensation concerns, and a proposal for your budgets.

bottom of page